Knowledge
How condensing and back pressure steam turbines differ, and which one fits a site.
What is the difference between a condensing and a back pressure steam turbine? A condensing steam turbine exhausts into a condenser below atmospheric pressure and turns as much steam energy as possible into electricity. A back pressure steam turbine exhausts steam at a pressure a process can still use, so it makes less power per tonne of steam but supplies heat to the plant at the same time. Extraction turbines combine both by taking process steam out at one or more stages.
Short answer: A condensing steam turbine exhausts into a condenser below atmospheric pressure and turns as much steam energy as possible into electricity. A back pressure steam turbine exhausts steam at a pressure a process can still use, so it produces less power per tonne of steam but supplies heat to the plant at the same time. Extraction turbines combine both by taking process steam out at one or more stages.
| Condensing turbine | Back pressure turbine | |
|---|---|---|
| Exhaust | Into a condenser, below atmospheric pressure | At a process pressure above atmospheric |
| Main product | Electricity | Process steam and electricity |
| Power per tonne of steam | Higher | Lower |
| Cooling system | Needs condenser and cooling water or air cooling | No condenser for the exhaust steam |
| Typical sites | Power plants, combined cycle plants, waste to energy | Paper mills, refineries, chemical plants, sugar and palm oil mills |
| Runs best when | Power demand is high and heat has no use | The site needs steam all the time |
If the site needs process steam continuously, a back pressure or extraction turbine uses the steam twice, first for power and then for heat. If only electricity is needed, a condensing turbine gives more power from the same steam.
A condensing turbine that also takes steam out at one or more stages for process heat. It can follow changing heat and power demand.
Usually not in a simple way. Blading, exhaust casing and the steam path are designed for the original exhaust pressure. Choose the type that matches the site from the start.
Live steam pressure and temperature, steam mass flow, the required exhaust or back pressure, extraction pressures and flows, generator frequency and the site cooling conditions. A used turbine fits only when these values match the boiler and the process.
LKS 360-SCHREINER LLC lists used steam turbines and steam turbine generator sets on behalf of their owners: steam turbines. More answers in the steam turbine FAQ
More detail: buyer guide, how we work, inventory.
Send type, output, frequency and fuel. We reply with matching offers.
Contact